Shearbeam Loadcells
Download Shearbeam Loadcell factsheet here
CL H8C series single ended shear beam is designed for Low profile platform scale’s, Industrial Hopper’s, Bins, Tanks, Silo’s and Process control weighing applications. The CL H8C series shear beam capacities from 500kg to 10t. One end of the shear beam contains the mounting holes while the opposite end is where the loadcell is loaded. The loadcell should be mounted on a flat smooth surface with high strength hardened bolts. Dedicated mounting kits are available to make installation under Hoppers, Bins, and Tanks and Silo a simple process. The CL H8C series Shearbeam is constructed of tool steel and is nickel plated and will stand the test of time in most environments.
|
SPECIFICATIONS |
|
|
|
cAPACITY |
Kg/ Tons |
500KG, 1000KG, 1500KG, 2000KG, 2500KG, 5000KG & 10,000KG |
|
Accuracy: |
|
C3 |
|
Approvals: |
nmax |
OIML R60 C3, Certificates No. R60/2000-CN-00.02 |
|
Maximum number of verification intervals: |
Vmin |
3000 |
|
Minimum loadcell verification interval |
(%FS) |
Emax/10000 |
|
Combined error |
(%FS/30min) |
≤±0.020 |
|
Creep |
(%FS/10°C) |
≤±0.016 |
|
Temperature effect on sensitivity |
(%FS/10°C) |
≤±0.011 |
|
Temperature effect on zero |
(mv/v) |
≤±0.015 |
|
Output sensitivity |
(Ω) |
3.0±0.003 |
|
Input resistance |
(Ω) |
350±3.5 |
|
Output resistance |
(MΩ) |
350±3.5 |
|
Insulation resistance |
(%FS) |
≥5000 (50VDC) |
|
Zero balance |
(°C) |
1.0 |
|
Temperature, compensated |
(°C) |
-10°C - 40°C |
|
Temperature, operating |
(V) |
-35°C - 70°C |
|
Excitation, recommended |
(V) |
5 ~ 12 (DC) |
|
Excitation, max |
(%FS) |
18 (DC) |
|
Safe overload |
(%FS) |
150% |
|
Ultimate overload |
|
300% |
|
Cable Length |
|
500kg-2000kg @ 4 mtrs 2,500kg-10,000kg @ 6 mtrs |
|
Wiring |
|
Adopt shielded, 4 conductor cable: Ø 5mm Input (+) Red, Output (-) White, Input (-) Black, Output (+) Green |
|
IP rating |
|
IP67 |